How To Interconnect Kidde Smoke Alarms

How To Interconnect Kidde Smoke Alarms – You are signed in with another tab or window. Reload to refresh your session. You have exited another tab or window. Reload to refresh your session. You switched accounts in another tab or window. Reload to refresh your session.

The original “dumb” smoke detector connection sounds the siren of all interconnected smoke detectors when a 9 to 12 volt DC signal (referenced to neutral/white) is continuously present on the signal wire (red). This is how all connected smoke alarms indicate a fire condition.

How To Interconnect Kidde Smoke Alarms

How To Interconnect Kidde Smoke Alarms

However, modern interconnected detectors are capable of detecting carbon monoxide and other conditions. When these conditions are flagged, they must be identified as something other than a smoke alarm from other detectors. Ideally, all dumb smoke detectors that share the interconnect signal should ignore these signals, even if they are not designed with this multiplexed signaling.

I12060ca 120v Ac Smoke Alarm With 9v Front Load Battery Backup

Kidde created such a mechanism in 2000 and apparently patented it (6,791,453; now probably expired…?). Although I think a patent for something like this is pretty silly, in this case it’s good news for us because it means we have some documentation!

A communication protocol is presented for the use of interconnected detectors for hazardous conditions such as smoke and carbon monoxide detectors for use in homes and other structures. This communication protocol provides conventional signaling to indicate the presence of a smoke condition, which requires the generation of a temporal smoke pattern from all interconnected detectors. The protocol further defines a signaling method whereby conventional smoke detectors that are unable to provide time patterns other than those required for a smoke alarm condition will not be sent to an operational alarm condition upon receipt of a signal. different from a conventional smoke alarm. . . This communication protocol defines a pulse signal to indicate a smoke-free alarm condition with a duration that will not trigger conventional smoke alarms. To allow the transmission of multiple alarm messages for hazardous conditions, as well as the transmission of additional control signals for hazardous condition detectors, the communication protocol uses a multi-bit signal transmitted over the conventional single-signal wire I/O line. currently existing interconnection. Using the 8-bit alarm signal, a variety of dangerous conditions can be signaled, as well as operating conditions such as test, silence, reset, low battery, etc. Also presented are combination detectors for smoke, carbon monoxide, and hazardous conditions that use the communication protocol presented here.

Means carbon monoxide alarm. However, it does cover the basic theory of operation and coding of the protocol. The information in the patent seems to cover more than enough to allow sufficiently motivated people to reverse engineer undocumented details.

In the hot zone we will have connections to the black, white and red lines of the smoke alarms as well as a small power supply using passive components giving us 9v and 5v. We use the 5V output to drive the ATTiny which monitors the signal line (RED). The ATTiny has three pins that it uses to drive opto-isolators.

Kidde Smoke & Carbon Monoxide Detector, Hardwired, Interconnect Combination Smoke & Co Alarm With Battery Backup, Voice Alert

A lot less stuff needs to be in the hot zone, mainly because we need that thing to function properly when the power goes out. This means that the only power we can rely on is the 12V input. We need some sort of isolated power supply from 9-12V to 9V for signaling. If we want to do this, we might as well have an op amp input for the red wire so we can have high z (safer).

In the safe area we have pins for the power input (9v-12v) as well as pins for three outputs and one input that is connected to the opto-isolators.

Sign up for free to join this conversation on GitHub. Already have a user? Sign in to comment

How To Interconnect Kidde Smoke Alarms

Kidde smoke alarms manual, kidde smoke alarms recall, costco kidde smoke alarms, kidde wireless smoke alarms, kidde smoke alarms, kidde smoke alarms i12060, interconnect smoke alarms, kidde smoke alarms troubleshooting, recalled kidde smoke alarms, kidde smoke alarms 1275, kidde smoke alarms beeping, kidde interconnected smoke alarms