Kidde Smoke And Carbon Monoxide Alarm Manual – Thank you for purchasing the Kidde Carbon Monoxide Combination Smoke Alarm Model # KN-COSMXTR-BA. This alarm is ideal as a single station. This alarm has a ten-year warranty. Please take a few minutes to read this guide carefully and save it for future reference. Teach children how to respond to alarms and not to play with the device. Your Kidde Smoke/CO Alarm is designed to detect smoke and carbon monoxide from any fuel source in the home. It is not intended for use in a recreational vehicle (RV) or boat. If you have questions about how the alarm works or how to set up the alarm, please call our toll-free product support line at 1-800-880-6788. This 24-page guide will help you find the right security systems to keep your home safe.

A carbon monoxide (CO) alarm monitors the atmosphere to indicate the presence of CO. It vibrates when CO is too high and when CO is too low for too long (see page 21 for alarm timing). ). When the CO condition meets one of these conditions, an alarm/beep will sound along with a flashing red light. The carbon monoxide sensor uses electrochemical technology.

Kidde Smoke And Carbon Monoxide Alarm Manual

Kidde Smoke And Carbon Monoxide Alarm Manual

Warning: This alarm only indicates the presence of carbon monoxide in the sensor. Carbon monoxide is found in some areas.

Kidde 21010408 N Download Instruction Manual Pdf

People with medical conditions may consider using warning devices that provide audible and visual signals for carbon monoxide concentrations below 30 ppm. Installation guide

IMPORTANT: THE WEATHER MUST BE CLEAR OR CLOSE TO IT. NOT FOR PLATFORM DEVICE USE! Enter as details ONLY!

Kidde Safety recommends installing alarms in the following locations. For maximum protection, we recommend installing alarms on all levels of a multi-storey building, including all rooms, balconies, finished areas and basements. Install alarms at both ends of a bedroom, hallway or main room if the hallway or room is more than 9.1m long. If you only have one alarm, make sure it is in the hallway outside the bedroom or in the master bedroom. Make sure the alarm goes off in all rooms.

Get an alarm in all rooms where someone is sleeping when the door is closed. A closed door can prevent a sleeper from being awakened by an alarm that is not in the room. Smoke, heat and combustible materials rise from the ceiling and spread horizontally. By placing the signal in the ceiling in the middle of the room, it gets closer to the rest of the room. Roofing is preferable when building simple houses. When mounting the alarm on the ceiling, place it at least 4″ (10 cm) from a side wall (see Figure 1). When mounting the alarm on a wall, use an interior wall that has at least a 4″ edge to the alarm. (10 cm) and 12″ (30.5 cm) below the ceiling (see Figure 1).

Kidde Hardwired Interconnectable Smoke And Carbon Monoxide Detector With Aa Battery Backup And Voice Alerts 21032082

Install smoke detectors on a sloped, high, or sloping roof or within 3 feet (0.9 m) of the highest point (measured horizontally). NFPA 72 states that “Smoke detectors in rooms with ceilings sloping horizontally from 1 foot to 8 feet (.3 m-2.4 m) shall be located at a distance from the room.”

NFPA 72 states: “The alarm line shall be located within 3 feet (0.9 m) of the ceiling, measured horizontally” (see Figure 2).

Modern motorhomes are designed and built to save energy. Install smoke/gas detectors as recommended above (see recommended installation instructions and Figure 1). In older buildings that are not properly insulated, excessive heat or cold can be transferred from the outside to the inside through poorly insulated walls and ceilings. This can create a thermal barrier that can prevent smoke from reaching a ceiling mounted alarm. In such homes, mount the smoke/CO alarm on an interior wall with the edge of the alarm 10 cm above and 30.5 cm below the ceiling (see Figure 2). If you are unsure about the insulation of your motorhome, or if you notice that the outer walls and roof are hot or cold, ONLY install the alarm on the inner wall!

Kidde Smoke And Carbon Monoxide Alarm Manual

WHAT TO INSTALL ACCORDING TO STANDARD 72 OF THE NATIONAL FIRE PROTECTION ASSOCIATION (National Fire Protection Association, Batterymarch Park, Quincy, MA 02269).

Optical Smoke Alarm

WARNING – This product is intended for environmental use. It is not intended to test compliance with OSHA standards.

Do not insert mirrors, kitchens, fireplaces and bathrooms! STAY AT LEAST 5 FEET FROM ANY BURNING EQUIPMENT.

Do not locate within 3 feet (0.9 m) of: A kitchen or bathroom door with a tub or shower, forced air vents used for heating or cooling, ceiling or whole-house fans, or other high-rise buildings. air zones. Avoid places that are very dusty, dirty or oily. Dust, oil or household chemicals can contaminate the alarm sensors and cause them to malfunction.

Install the alarm where curtains or other objects cannot block the sensor. Smoke and CO must reach the sensors for this to be detected correctly. Do not install flat roofs, roof “A” and slate. Avoid wet and damp areas.

Kidde Smoke & Carbon Monoxide Detector, Aa Battery Powered, Led Warning Light Indicators & Smoke Detector, 9v Battery Operated Smoke Alarm, Test Reset Button, Battery Included

Keep one (1) foot away from fluorescent lights, electrical noise may cause alarm. Do not leave in the sun and avoid places with insects. Excessive heat will affect the sensitivity of the smoke/CO alarm. Do not install in locations where the temperature is above 40 degrees Fahrenheit (4.4˚C) or above 100 degrees Fahrenheit (37.8˚C), such as garages and unfinished rooms. Do not place in places where the relative humidity (RH) exceeds 95%, do not move. Place it away from doors and windows that can be opened outwards.

WARNING: Due to the loudness of the alarm (85 decibels), stay away from the device at all times during the test.

After installation, test the INSTRUMENT ELECTRONICS by pressing and releasing the test/reset button. You will then hear a series of beeps and warnings:

Kidde Smoke And Carbon Monoxide Alarm Manual

Weekly testing required! If at any time it does not work as described, make sure the power is properly connected and the battery does not need to be replaced. Remove dust and other debris from the device. If that doesn’t work, call our customer support line at 1-800-880-6788.

Kidde Interconnectable Smoke Alarms, With Hush, Photoelectric, 1/ea

The HUSH function has the option of temporarily deactivating the smoke detector for approx. 9 minutes. This should only be used when known alarms, such as cooking smoke, have triggered the alarm. You can put the alarm in HUSH mode by pressing the test/reset button. If the smoke is not too dense, the alarm will turn off immediately, the device will announce “SMOKE MODE ENABLED” and the green LED will flash every 2 seconds for 9 minutes. This indicates that the smoke detector is temporarily disabled. is inactive. Your alarm will reset after 9 minutes. When the unit returns to normal operation after being in HUSH mode, it will announce “HUSH MODE DISABLED” and sound an alarm if smoke is still present. The HUSH function can be used repeatedly until the air is removed due to an alarm. While the unit is in HUSH mode, pressing the alarm test/reset button will also cancel the HUSH period.

WARNING: BEFORE USING THE ALARM DEVICE, DETERMINE WHERE THE SMOKE CAN BE CLEANED AND STAY LOW TO BE SAFE.

If the smoke/gas alarm gives a CO alarm, pressing the test/reset button will cancel the alarm.

If the CO condition that caused the alarm continues, the alarm will reset within 200 seconds (see page 21).

Kidde Smoke Detector, Battery Operated Smoke Alarm With Safety Light, Hush Feature

If the green light flashes every 10 seconds, the device has detected a CO error. If the CO sensor detects a CO level of 100 PPM or more since the last reset, it will be recorded via the highest level memory function. To find high level memory, press the test/reset button. If a reading of 100 PPM or more is registered, the unit will announce “Warning, Carbon Monoxide Detected.” If you’re away from home, this lets you see if there are 100 or more SOs while you’re away. By pressing the test/reset memory button, the memory is reset. It is reset when the battery is removed.

A countermeasure is provided to protect smoke/CO alarms. Activate the tamper proof feature by cutting four bolts into holes in the center of the reducer ring (see Figure 5A). When the posts are broken, a tamper proof plate is allowed for mounting the mounting bracket to the base.

Kidde smoke and carbon monoxide alarm battery, replacing kidde smoke and carbon monoxide alarm, amazon kidde smoke and carbon monoxide alarm, kidde nighthawk smoke and carbon monoxide alarm, buy kidde smoke and carbon monoxide alarm, kidde wired smoke and carbon monoxide alarm, kidde smoke alarm carbon monoxide, kidde smoke and carbon monoxide alarm replacement, kidde smoke and carbon monoxide alarm hardwired, kidde photoelectric smoke and carbon monoxide alarm, kidde combined smoke and carbon monoxide alarm, kidde wireless smoke and carbon monoxide alarm